Professionally inspected, tested, and serviced. Aging or degraded components have been replaced where necessary to restore performance as close as possible to original factory specifications.
Before Restoration
We evaluated the deck following an initial transport-operation issue involving the capstan motor area. The recording/playback preamplifiers, switches, and level controls were also identified for service.
During Restoration
Heads: We cleaned, demagnetized, and inspected the tape heads for wear.
Tape Path & Transport: We cleaned and inspected the capstan, pinch roller, guides, and tape path.
Brakes & Tension: We inspected and adjusted the braking and tape-tension mechanisms.
Motors: We inspected, cleaned, and lubricated the transport motors.
Capstan Circuit: We inspected the capstan motor circuitry and its electrical components.
Capacitors & Boards: We tested capacitors, replaced out-of-spec units, cleaned boards, and reinforced solder joints.
Record/Playback Electronics: We inspected the preamplifier circuits and signal paths.
Switches, Controls & Jacks: We cleaned and serviced operating controls and signal connections.
VU Meter Lighting: We serviced the meter lighting using new lighting components.
Reverse-Playback Mechanism: We inspected the automatic reverse controls and tape-sensing mechanism.
After Restoration / Final Testing
We performed the standard 72-hour burn-in procedure.
We tested playback, recording, fast-forward, rewind, and automatic reverse functions.
We checked tape transport operation at both available tape speeds.